ICP-MS6880測定5種中藥注射液中重金屬及有害元素
關(guān)鍵詞:電感耦合等離子體質(zhì)譜法;中藥注射液;重金屬及有害元素;直接稀釋法
建立電感耦合等離子體質(zhì)譜法(ICP-MS)測定復方蒲公英注射液、野菊花注射液、腫節(jié)風注射液、白花蛇舌草注射液和夏天無注射液中銅(Cu)、砷(As)、鎘(Cd)、鉛(Pb)和汞(Hg)5種重金屬及有害元素含量的方法。樣品用2%硝酸(V/V)直接稀釋,以72Ge、115In、185Re為內(nèi)標,采用ICP-MS測定溶液中元素含量。方法學驗證表明:Cu、As、Cd、Pb在0.5~50 μg/L和Hg在0.5~10 μg/L的質(zhì)量濃度范圍內(nèi)線性關(guān)系良好(r2>0.999);低、中、高3種濃度水平,復方蒲公英注射液、夏天無注射液、腫節(jié)風注射液、野菊花注射液、白花蛇舌草注射液中5種元素的平均回收率(n=3)分別為90.7%~121.2%、83.4 %~119.9%、90.8%~116.3%、86.4%~109.0%、85.0%~118.0%,重復性RSD(n=3)分別為1.4%~9.8%、0.2%~6.7%、0.4%~7.4%、0.6%~10.0%、0.1%~11.1%;5種注射液中Cu、As、Cd、Pb、Hg的LOQ分別為0.002 1 mg/L、0.001 6 mg/L、0.000 56 mg/L、0.001 8 mg/L、0.001 7 mg/L,滿足方法學驗證的要求。各3批次實際中藥注射液樣品的測試結(jié)果表明,5種元素含量均小于限量值,說明其安全風險較小。方法操作簡便、快速、靈敏度高、準確度好,適合5種注射液中的Cu、As、Cd、Pb、Hg等有害元素含量的測定,為其他中藥注射液中元素雜質(zhì)分析方法的建立提供參考。
Determination of heavy metals and harmful elements in five traditional
Chinese medicine injections using inductively coupled plasma mass spectrometry
(ICP-MS)
ZHANG Chunhua, CHEN Chuntao, HAN Bikai, LI Ziyi, CHEN Liang, ZHU Zhixin, WU
Huiqin, HUANG Xiaolan
Guangdong Provincial Public Laboratory of Analysis and Testing Technology,
Guangdong Engineering and Technology Research Center for Quality and Safety of
Traditional Chinese Medicine, China National Analytical Center, Guangzhou,
Guangzhou 510070, China
Abstract: A method for the determination of heavy metals and
harmful elements(Cu, As, Cd, Pb, Hg) in five traditional Chinese medicine
injections using inductively coupled plasma mass spectrometry (ICP-MS) was
developed and validated. The traditional Chinese medicine injections was
pretreated by diluting with 2% nitric acid (V/V), then the five target
elements and internal standard elements (72Ge, 115In, 185Re)
were detected by ICP-MS. The established method was fully validated. The
calibration curves were linear over a range of 0.5-50 μg/L for Cu, As, Cd, Pb, and 0.5-10 μg/L for Hg, and the correlation coefficients (r2)
were higher than 0.999. At three spiked levels (low, medium and high
concentration), the average recoveries (n=3) for the five elements in
Fufang Pugongying injection, Xiatianwu injection, Zhongjiefeng injection,
Yejuhua injection, Baihuasheshecao injection were 90.7%-121.2%, 83.4%-119.9%,
90.8%-116.3%, 86.4%-109.0%, 85.0%-118.0%, respectively, with the RSDs (n=3)
were 1.4%-9.8%, 0.2%-6.7%, 0.4%-7.4%, 0.6%-10.0%. 0.1%-11.1%. The limits of
quantitation (LOQ) for Cu, As, Cd, Pb, Hg in five traditional Chinese medicine
injections were 0.002 1, 0.001 6, 0.000 56, 0.001 8, 0.001 7 mg/L. Three
batches of five actual traditional Chinese medicine injections were analyzed
using the developed method, and the results showed that the contents of Cu, As,
Cd, Pb and Hg were all less than the limits. The method, proved to be easy to
handle, rapid and sensitive, meets the method validation requirements, and was
suitable for the determination of the heavy metals and harmful elements in five
traditional Chinese medicine injections. It also can supply a reference for the
determination of the elemental impurities in the other traditional Chinese
medicine injections
Keywords: inductively coupled plasma mass spectrometry
(ICP-MS);traditional Chinese medicine injections;heavy metals and harmful
elements;direct dilution
關(guān)鍵詞:電感耦合等離子體質(zhì)譜法;中藥注射液;重金屬及有害元素;直接稀釋法